Inicio  /  Applied Sciences  /  Vol: 12 Par: 15 (2022)  /  Artículo
ARTÍCULO
TITULO

Titanium Surface Analysis after Instrumentation with Different Burs Simulating the Implantoplasty Technique: A Pilot In Vitro Experimental Study

Sergio Alexandre Gehrke    
Berenice Anina Dedavid    
Germán Odella Colla    
Piedad N. De Aza and Leticia Pérez-Díaz    

Resumen

(1) Background: The present pilot in vitro study evaluated, physically and biologically, the effects produced by the wear of the titanium surface using different drill models. (2) Methods: Titanium disks were subjected to wear using four different burs and accordingly divided into the following test groups (n = 12 disks per group): Tungsten Burs (TB group), Tungsten Carbide Burs (TCB group), Coarse-Grained Diamond Burs (CGB group), and Fine-Grained Diamond Burs (FGB group). As a control group (CON group), titanium disks with a smooth surface (machined) were used. The samples were subjected to atomic force microscopy (AFM), profilometry analysis, scanning electron microscopy (SEM), and cell viability and adhesion assessments. (3) Results: The values of the measured roughness parameters showed statistical differences among the five groups (p = 0.0035 for Ra and p = 0.0010 for Rz). All test groups showed an important difference statistically (p = 0.0032) to the CON group for the cell viability and adhesion analysis. The data of cell absorbance at 570 nm were 0.4122 ± 0.05 for the CON group, 0.1354 ± 0.02 for the TB group, 0.123 ± 0.01 for the TCB group, 0.1414 ± 0.02 for the CGB group, and 0.1216 ± 0.03 for the FGB group. Additionally, the cell count showed the following adherence percentages: 57.6 ± 4.6% for the CON group, 22.9 ± 3.3% for the TB group, 23.4 ± 2.9% for the TCB group, 22.5 ± 3.1% for the CGB group, and 23.7 ± 3.3% for the FGB group. However, no statistical differences were found among the four test groups analyzed (p = 0.3916). (4) Conclusions: The results showed that the changes produced on the surface by the four different bur models altered the topography characteristics and affected the cell viability and adhesion in comparison with the control group.

 Artículos similares

       
 
Ghada Alrabeah, Jonathan C. Knowles and Haralampos Petridis    
The improved peri-implant bone response demonstrated when utilizing the platform-switching concept may result from the reduced levels of metal ions released from implant?abutment surfaces to the surrounding tissues. These corrosion products may play a ma... ver más
Revista: Applied Sciences

 
Muhammad Ayyaz Khan, Muhammad Ali Khan, Shahid Aziz, Muhammad Iftikhar Faraz, Abdul Malik Tahir, Syed Husain Imran Jaffery and Dong-Won Jung    
Titanium grade 9 (Ti-3Al-2.5V) stands out as a preferred material in various industrial applications because of its suitable properties. Its applications span diverse sectors, including precision manufacturing, where it is utilized to produce honeycomb s... ver más
Revista: Applied Sciences

 
María del Carmen Marco de Lucas, Franck Torrent, Gianni-Paolo Pillon, Pascal Berger and Luc Lavisse    
Surface laser treatment (SLT) using nanosecond IR lasers has been shown to improve the tribological behaviour of titanium. Here, we studied the fretting wear of SLT-functionalized pure titanium in a mixture of reactive gases O2" role="presentation" style... ver más
Revista: Coatings

 
Younes Belbellaa, Nabil Kribes, Mohamed Athmane Yallese, Habiba Lekmine, Smail Boutabba, Abderrezak Bezazi     Pág. 1 - 11

 
Mehrdad Koohnavard, Berkan Celikten, Arda Buyuksungur and Kaan Orhan    
This study aims to compare the shaping efficiency of the nickel?titanium instrument systems, One Reci and ProTaper Ultimate, using micro-CT (micro-computed tomography) in traditional and conservative endodontic access cavities. The experimental groups we... ver más
Revista: Applied Sciences