Elaborado por el Consejo de Políticas de Infraestructura (CPI), este documento constituye una hoja de ruta estratégica para orientar la inversión y la gestión de infraestructura en Chile. Presenta propuestas organizadas en siete ejes estratégicos, sin centrarse en proyectos específicos, sino en influir en las decisiones de política pública para promover una infraestructura que conecte territorios, genere oportunidades y eleve la calidad de vida de la población.
ARTÍCULO
TITULO

Experimental Study on Operating Characteristic of a Combined Radiant Floor and Fan Coil Cooling System in a High Humidity Environment

Xuwei Zhu    
Jiying Liu    
Xiangyuan Zhu    
Xiaole Wang    
Yanqiu Du and Jikui Miao    

Resumen

The combined radiant floor and fan coil cooling (RFCAFC) system is widely used due to its high comfort and large energy saving potential. In this study, as an example, the combined RFCAFC system was studied in a high humidity environment in Jinan, Shandong Province, China. The novelty of the combined RFCAFC system lies in its ability to automatically adjust the water supply temperature of the radiant floor and fan coil in real time according to outdoor meteorological conditions, achieving thermal comfort while eliminating the likelihood of condensation on the radiant floor surface. Days with similar outdoor meteorological conditions were grouped, and the comfort level and hourly cooling performance coefficient (EERh) of different operating strategies for different outdoor meteorological conditions were monitored along with other evaluation indicators. The RFCAFC had good energy efficiency and comfort in a high humidity room environment. This study showed that the indoor vertical air temperature difference ranged from 1.6 to 1.8 °C, which met the ASHRAE55-2017 standard. The radiant floor surface temperature uniformity coefficient (S) fluctuated between 0.7 and 1.0, and the time it took the radiant floor surface temperature to reach 63.2% of the total variability range (t63) for different operation strategies based on different outdoor meteorological conditions ranged between 4.4 and 4.7 h, which was within the normal range. The proportion of the total cooling capacity contributed by fan coil cooling under low temperature and high humidity (LH), high temperature and low humidity (HL), and medium temperature and medium humidity (MM) were 68.0%, 73.8%, and 71.7%, respectively. Based on this study, the following recommendations for the combined cooling system can be made: (1) When the outdoor humidity is high, the radiant floor system should be turned on early to provide cooling capacity. When the outdoor temperature is high, the fan coil system should be turned on early to reduce the indoor temperature. (2) To reduce energy consumption and achieve efficient operation of the system, the radiant floor system should be continuously operated to maximize its contribution to the cooling capacity, while the fan coil can be operated intermittently. Natural cooling can be integrated to provide additional cooling capacity to the room in the hours preceding occupation (i.e., 7:00?9:00). (3) The operation strategy of the combined cooling system must be able to respond in real time to changes in outdoor meteorological conditions to prevent discomfort in times of extreme heat or humidity.

Artículos similares

Hemos preparados una selección de otros artículos que pudieran ser de tu interés
Xuan Mo, Zhijun Yuan, Yigang Jia, Liangjian Lu, Xianglan Wei and Naiwen Ke    
In this paper, a novel T-shaped steel?concrete composite shear wall (TSCCW) is proposed. Low-cycle reciprocating tests were carried out on the TSCCW to investigate its performance in terms of its damage characteristics, hysteretic properties, energy diss... ver más
Revista: Buildings
Adel Almoslh, Falah Alobaid, Christian Heinze and Bernd Epple    
The influence of pressure on the gas/liquid interfacial area is investigated in the pressure range of 0.2?0.3 MPa by using a tray column test rig. A simulated waste gas, which consisted of 30% CO2 and 70% air, was used in this study. Distilled water was ... ver más
Revista: Applied Sciences
Jian Wu, Ying Jiang, Jian Zhou, Liangjie Hu, Jianhui Wang and Weigao Ding    
The mechanical performance of existing buildings degrades over time, and even if the mechanical performance meets the requirements, some buildings will have new usage needs, necessitating the reinforcement and renovation of buildings. Therefore, this pap... ver más
Revista: Buildings
Yilin Li, Zewen Liu, Yidong Li, Ying Chen, Ziding Bai, Huaiwang Jing, Ruiyan Zhang and Jianbo Chen    
The negative ion air purifier (NIAP) has been used for capturing particulate matter. Nevertheless, the knowledge on its effectiveness in removing other air pollutants such as ammonia gas remains limited. In this study, the effect of an NIAP for indoor am... ver más
Revista: Buildings
Wei Lu, Yu Zou, Xingyu Luo, Jun Song and Haiqing Li    
Compared to conventional reinforced concrete (RC) piers, self-centering rocking piers exhibit better seismic resilience and sustain minor damage. However, their construction typically relies on prefabrication. Moving large, prefabricated components can b... ver más
Revista: Buildings