Inicio  /  Buildings  /  Vol: 11 Par: 4 (2021)  /  Artículo
ARTÍCULO
TITULO

Indoor Airflow Distribution in Repository Design: Experimental and Numerical Microclimate Analysis of an Archive

Karin Kompatscher    
Rick P. Kramer    
Bart Ankersmit and Henk L. Schellen    

Resumen

The majority of cultural heritage is stored in archives, libraries and museum storage spaces. To reduce degradation risks, many archives adopt the use of archival boxes, among other means, to provide the necessary climate control and comply with strict legislation requirements regarding temperature and relative air humidity. A strict ambient indoor climate is assumed to provide adequate environmental conditions near objects. Guidelines and legislation provide requirements for ambient indoor climate parameters, but often do not consider other factors that influence the near-object environment, such as the use of archival boxes, airflow distribution and archival rack placement. This study aimed to provide more insight into the relation between the ambient indoor conditions in repositories and the hygrothermal conditions surrounding the collection. Comprehensive measurements were performed in a case study archive to collect ambient, local and near-object conditions. Both measurements and computational fluid dynamics (CFD) modeling were used to research temperature/relative humidity gradients and airflow distribution with a changing rack orientation, climate control strategy and supply as well as exhaust set-up in a repository. The following conclusions are presented: (i) supplying air from one air handling unit to multiple repositories on different floors leads to small temperature differences between them. Differences in ambient and local climates are noticed; (ii) archival boxes mute and delay variations in ambient conditions as expected?however, thermal radiation from the building envelope may have a large influence on the climate conditions in a box; (iii) adopting night reduction for energy conservation results in an increased influence of the external climate, with adequate insulation, this effect should be mitigated; and (iv) the specific locations of the supply air and extraction of air resulted in a vertical gradient of temperature and insufficient mixing of air, and adequate ventilation strategies should enhance sufficient air mixing in combination with the insulation of external walls, and gradient forming should be reduced.

 Artículos similares

       
 
Weixin Zhao, Simo Kilpeläinen, Wertti Bask, Sami Lestinen and Risto Kosonen    
To maintain proper indoor air quality and increase energy efficiency, a demand-control ventilation (DCV) system has become a popular solution. This paper reports the findings of a field study conducted on the performance of the DCV systems in eight publi... ver más
Revista: Buildings

 
Ying Hong Pheh, Shane Kyi Hla Win and Shaohui Foong    
Even as human?robot interactions become increasingly common, conventional small Unmanned Aircraft Systems (sUAS), typically multicopters, can still be unsafe for deployment in an indoor environment in close proximity to humans without significant safety ... ver más
Revista: Drones

 
Eusébio Conceição, João Gomes, Maria Manuela Lúcio, Maria Inês Conceição and Hazim Awbi    
This paper presents a comparative study of a clean technology based on a DSF (double skin facade) used in winter conditions in the occupied buildings comfort improvement, namely the thermal comfort and air quality. The performance of a solar DSF system, ... ver más

 
Rand Talib and Nabil Nassif    
According to EIA, the Heating Ventilation and Air Conditioning (HAVC) systems account for about 25% of the U.S.?s total commercial building?s energy use. Therefore, advanced modeling and optimization methods of the system components and operation offer g... ver más
Revista: Buildings

 
Philip Mckeen and Zaiyi Liao    
Airflow into stairwells due to stack effect is a concern affecting fire safety, energy performance, and indoor air quality. Stack effect in tall buildings can create significant pressure differentials in vertical shafts when differences in outdoor and in... ver más
Revista: Buildings