A Beam Monitor for Ion Beam Therapy Based on HV-CMOS Pixel Detectors

Alexander Dierlamm    
Matthias Balzer    
Felix Ehrler    
Ulrich Husemann    
Roland Koppenhöfer    
Ivan Peric    
Martin Pittermann    
Bogdan Topko    
Alena Weber    
Stephan Brons    
Jürgen Debus    
Nicole Grau    
Thomas Hansmann    
Oliver Jäkel    
Sebastian Klüter and Jakob Naumann    

Resumen

Particle therapy is a well established clinical treatment of tumors. More than one hundred particle therapy centers are in operation world-wide. The advantage of using hadrons like protons or carbon ions as particles for tumor irradiation is the distinct peak in the depth-dependent energy deposition, which can be exploited to accurately deposit doses in the tumor cells. To guarantee this, high accuracy in monitoring and control of the particle beam is of the utmost importance. Before the particle beam enters the patient, it traverses a monitoring system which has to give fast feedback to the beam control system on position and dose rate of the beam while minimally interacting with the beam. The multi-wire chambers mostly used as beam position monitors have their limitations when a fast response time is required (drift time). Future developments such as MRI-guided ion beam therapy pose additional challenges for the beam monitoring system, such as tolerance of magnetic fields and acoustic noise (vibrations). Solid-state detectors promise to overcome these limitations and the higher resolution they offer can create additional benefits. This article presents the evaluation of an HV-CMOS detector for beam monitoring, provides results from feasibility studies in a therapeutic beam, and summarizes the concepts towards the final large-scale assembly and readout system.

 Artículos similares

       
 
Roland Schnuerer, Jacinta Yap, Hao Zhang, Tomasz Cybulski, Tony Smith, Guido Haefeli, Olivier Girard, Tomasz Szumlak and Carsten Welsch    
Knowledge of the beam properties in proton therapy through beam monitoring is essential, ensuring an effective dose delivery to the patient. In clinical practice, currently used interceptive ionisation chambers require daily calibration and suffer from a... ver más
Revista: Instruments

 
Zhanzhong Yin, Dazhe Feng and Wenwei Yang    
In the current design of steel eccentrically braced frames (EBFs), the yielding link is coupled with the floor beam. This causes the design of cross-sectional dimensions of links to be enlarged, resulting in over-designed structures and foundations, and ... ver más
Revista: Applied Sciences

 
Sudharsan Srinivasan and Pierre-André Duperrex    
Measurement of the proton beam current (0.1?40 nA) at the medical treatment facility PROSCAN at the Paul Scherrer Institut (PSI) is performed with ionization chambers. To mitigate the scattering issues and to preserve the quality of the beam delivered to... ver más
Revista: Instruments

 
B. MÉNDEZ ANTONIO,R. B. DA SILVEIRA,E. CAETANO,V. MAGAÑA,R. DOMÍNGUEZ    
In México, there is a network of 12 meteorological radars to monitor intense convective systems. Data from Cerro de la Catedral Doppler radar, 40 km northwest of México City, have been used to obtain precipitation rates estimates during intense precip... ver más
Revista: Atmósfera