ARTÍCULO
TITULO

Outdoor Air Quality and Antibiogram Characteristics of Bacterial Isolates of Akure City Abattoirs, Nigeria

Olubukola Olayemi Olusola-makinde    

Resumen

Air sampling of Onyearugbulem and FUTA abattoirs was carried out to evaluate their quality. Air sampling was done using the open-settling method on general and selective agar media of the gutter, sleeping bench, slaughtering floor dumpsite, slaughtering table and roof of the abattoirs.  Using standard methods, Presumptive identification of the bacterial isolates was carried out. An array of ten (10) conventional antibiotics was used to assay the antibiotic susceptibility characteristics of the bacterial isolates. Multiple antibiotic sensitivity index (MARI) was determined for isolated bacteria. At Onyearugbulem abattoir, the total Escherichia coli count ranged from 3.6×10 cfu/ml from the gutter and slaughtering table to 6.5×10 cfu/ml from the slaughtering floor, while the total bacterial count ranged from 1.34×102 cfu/ml from dumpsite to 2.55×102 cfu/ml from the gutter, the total coliform count ranged from 2.8× 10 cfu/ml from slaughtering floor to 4.1×10 cfu/ml from sleeping bench. Several bacteria were presumptively isolated. These include: Micrococcus sp., Bacillus sp., Staphylococcus aureus, Escherichia coli, Proteus sp., Enterobacter aerogenes and Aeromonas sp. Ciprofloxacin (10 µg) had an inhibitory effect on all the Gram positive bacterial isolates with the highest inhibitory activity on S. aureus at 24.00 mm, and the Gram negative bacteria with the highest inhibitory activity on E. coli at 21.00 mm. Micrococcus sp. had the highest MARI of 0.8. These findings reveal the presence of multiple-antibiotic resistant bacteria in Onyearugbulem and FUTA abattoirs? atmosphere. There is therefore need for routine environmental sanitation of the slaughterhouses.

 Artículos similares

       
 
Anna Pacak, Anna Jurga, Korneliusz Sierpowski, Magdalena Panek, Agata Skolowska and Demis Pandelidis    
In this study, a multi-stage regenerative-cross-flow dew-point evaporative cooler performance is analyzed and compared to the performance of a regenerative dew-point evaporative cooler. The most beneficial configuration of the proposed exchanger was esta... ver más
Revista: Applied Sciences

 
Awen Zhang, Na Deng, Zhengwei Long, Ruisen Hao, Changyu Shen and Guoqing Cao    
A Chinese commercial kitchen fume exhaust (CCKEF) system mainly consists of a wall-mounted canopy hood, air duct and terminal electrostatic purifiers, the capture and purification performance of which should be guaranteed to obtain satisfactory indoor an... ver más
Revista: Applied Sciences

 
Teresa Baptista, Marina Almeida-Silva, Dário Silva, Carlos Diogo and Nuno Canha    
Indoor Air Quality (IAQ) is a public and occupational health concern, as we are exposed to air pollutants daily given that we spend a great amount of our time in indoor environments. IAQ can be affected by numerous factors, from outdoor pollutants that g... ver más
Revista: Applied Sciences

 
Victor Norrefeldt, Florian Mayer, Britta Herbig, Ria Ströhlein, Pawel Wargocki and Fang Lei    
In the CleanSky 2 ComAir study, subject tests were conducted in the Fraunhofer Flight Test Facility cabin mock-up. This mock-up consists of the front section of a former in-service A310 hosting up to 80 passengers. In 12 sessions the outdoor/recirculatio... ver más
Revista: Aerospace

 
Monica Lilioara Chereche?, Nelu Cristian Chereche?, Adrian Alexandru Ciobanu, Sebastian Valeriu Hudi?teanu, Emilian Florin ?urcanu, Aurelia Bradu and Catalin George Popovici    
In the context of energy conservation and sustainable development, building design should take into account the energy efficiency criteria by using renewable energy sources. Double-skin facades (DSF) represent innovative energy-efficient techniques that ... ver más
Revista: Applied Sciences