Evaluating in-situ thermal transmittance measurement to analyze devia-tions between actual house thermal performance and modelled one by means of energy simulation software

Fahimeh Rezvani    
Ignacio Zabalza Bribián    

Resumen

 Energy diagnosis and check of the energy performance of traditional houses are becoming urgent and essential to achieving energy saving in the residential sector. The paper presents the results of experimental studies focused on the enhancement of the methods to assess the energy efficiency in traditional houses. It is focused on U-value as an indicator of thermal energy efficiency of traditional houses and involves in-situ measurement and the subsequent comparison with U-values calculated by a software tool. The method has been performed on thirteen walls made of stone, brick, solid mud and mixed materials. It has been concluded that in the case of masonries, the differences between the standards and in-situ measurement U-values varies considerably from 8% to 23.5%.  Besides, these differences are within a range of 4.7% to 12.8% in the brick construction houses, due to the different thermal conductivity of brick materials. 

 Artículos similares

       
 
Stefan Schönekerl, Astrid Weigert, Stephan Uhlig, Katharina Wellner, Richard Pörschke, Christel Pfefferkorn, Karsten Backhaus and André Lerch    
In this study, a lab-scale plant was designed to treat water in continuous flow condition using non-thermal plasma technology. The core was an electrode system with connected high-voltage (HV) pulse generator. Its potentials and limitations were investig... ver más
Revista: Water

 
Gylles Ricardo Stroher, Cosmo Damião Santiago     Pág. e40992
Heat can be used as an adjuvant treatment of many diseases and also as a powerful tool to help diagnose cancers, with the advantage to be a noninvasive exam. Some tumors may be best diagnosed by evaluating body temperature distribution, for instance, it ... ver más

 
Alvaro Antonio Ochoa Villa, José Ângelo Peixoto da Costa, Carlos Antonio Cabral dos Santos (Author)     Pág. e34969
This paper sets out to examine a small absorption chiller that uses the pair LiBr/ H2O with a 4.5 kW nominal capacity, using theoretical modeling and the characteristic equation method. The idea is to compare two ways of simulating and evaluating absorpt... ver más

 
Behzad Behnia, William Buttlar and Henrique Reis    
Low-temperature cracking is a major form of distress that can compromise the structural integrity of asphalt pavements located in cold regions. A review of an Acoustic Emission (AE)-based approach is presented that is capable of assessing the low-tempera... ver más
Revista: Applied Sciences

 
Seiichiro Ioka and Hirofumi Muraoka    
The energy available via microbial sulfate reduction was estimated for a Quaternary aquifer in northern Japan that is a candidate site for low temperature aquifer thermal energy storage. In evaluating whether microbial sulfate reduction proceeded or ceas... ver más
Revista: Water