Inicio  /  Atmósfera  /  Vol: 6 Núm: 4 Par: 0 (1993)  /  Artículo
ARTÍCULO
TITULO

Cooling and heating due to latent and sensible heat over the Yucatan continental shelf

J. HERNÁNDEZ TÉLLEZ    
J. ALDECO RAMÍREZ    
DAVID ALBERTO SALAS DE LEÓN    

Resumen

From meteorological data and sea surface temperatures taken during the oceanographic cruises PLAYUC (January 6 to 17, 1990) and YUCPLA (May 25 to June 4, 1990), conducted over the Yucatan Continental Shelf, the cooling and heating areas produced by the fluxes of latent (Qe) and sensible heat (Qt) were determined. The computation was done using the bulk aerodynamic equations. During PLAYUC, the line of SST - Ta = 0 (sea surface temperature minus air temperature) divided roughly the study area into two regions (east and west). This was caused by two moderated northers. At the west side the difference SST - Ta was between 1 and 4ºC, and at the lower east side the difference was between -1 to -3ºC. The values of Qe and Qt for the cooling area at the west were from 160 to 260 W/m2 and from 10 to 60 W/m2 respectively. At the east portion the diurnal contrast of Qewas observed at three small areas. North of Cabo Catoche a fog was present over a weak upwelling area, reducing the cooling rate due to Qe from 30 to below 10 W/m3 and the heating due to Qt to values around -5 to -6 W/m2. The average values during PLAYUC for Qe and Qtover the shelf were 140.92 and 14.88 W/m2, respectively. During YUCPLA, influence of moist and warm air from the East was observed. Two lines of SST - Ta = 0 divided the study area diagonally in two portions, northwest and southeast. The difference SST - Ta for the northwest portion was from -1 to 0ºC and for the southeast from -4 to 0ºC. During this second cruise the cooling was less intense and with weaker spatial contrast. At the NW portion two intrusions of Qe were observed, one toward the coast and another going offshore. At the SE portion a north-to-south tongue was observed. Similar to what was the case during PLAYUC, the upwelling and fog area promoted a heating due to condensation (Qe < 0). At the NW portion three well delineated regions of heating and cooling were observed, showing the diurnal variations. The average values during this cruise for Qe and Qt were 66.63 and 0.36 W/m2, respectively.

 Artículos similares

       
 
Dorin Moldovan    
This article introduces a novel nature-inspired algorithm called the Plum Tree Algorithm (PTA), which has the biology of the plum trees as its main source of inspiration. The PTA was tested and validated using 24 benchmark objective functions, and it was... ver más
Revista: Algorithms

 
Longhuang Xiao, Yuan Zhuang, Xilei Wu, Jialiang Yang, Yongjie Lu, Ying Liu and Xiaohong Han    
Immersion cooling is widely used for thermal management of servers. The two-phase immersion cooling, which transfers heat by boiling, possesses efficient temperature control ability under intensive heat generation. In the process of temperature control t... ver más
Revista: Applied Sciences

 
Mingke Li, Kepeng Huang and Xuemei Yi    
Laser cladding, a novel surface treatment technology, utilizes a high-energy laser beam to melt diverse alloy compositions and form a specialized alloy-cladding layer on the surface of the substrate to enhance its property. However, it can generate subst... ver más
Revista: Coatings

 
Uchechi Ukaegbu, Lagouge Tartibu and C. W. Lim    
Energy demand and consumption have, in recent times, witnessed a rapid proliferation influenced by technological developments, increased population and economic growth. This has fuelled research trends in the domain of energy management employing tri-gen... ver más
Revista: Algorithms

 
Artur Kulaszka, Józef Blachnio and Henryk Borowczyk    
The reliability and operational safety of an aircraft engine gas turbine are extremely important in terms of its operation. In the course of operation, these turbines undergo complex thermal, mechanical, aerodynamic, and chemical exhaust gas loads. Due t... ver más
Revista: Aerospace