Indoor Air Quality and Thermal Conditions in a Primary School with a Green Roof System

Nikolaos Barmparesos    
Margarita Niki Assimakopoulos    
Vasiliki D. Assimakopoulos    
Nikolaos Loumos    
Maria Aliki Sotiriou and Athanasios Koukoumtzis    

Resumen

This paper presents experimental results from a typical school building in Athens, equipped partly with a green roof system (GRS). Environmental monitoring took place in six classrooms located both under the concrete roof and the GRS sectors as well as in the immediate external environment during the warm and cold periods of a school year. Daily measurements of pollutants CO2, TVOCs (Total Volatile Organic Compound), PM1, PM2.5, and PM10 were performed in selected classes. Moreover, indoor ambient temperature (T) and relative humidity (RH) measurements were implemented in order to estimate the absolute humidity (AH) and assess the indoor environmental conditions. The results highlight that during summer, the GRS reduces temperature in a classroom on the top floor by about 2.8 °C, in comparison with the respective classroom under the concrete roof and that AH remained relatively stable for both classrooms. Amid winter, a reverse behavior occurs only for temperature. Moreover, air exchange rates (AER) were calculated by using the CO2 decay method for all of the classrooms. The results demonstrated insufficient ventilation for all experimental sights. Finally, concentrations of PM1, PM2.5 and PM10, were found to be relatively decreased, with average values of 0.79, 3.39, and 27.80 µg m-3. Levels of CO2 and TVOCs were elevated during class hours ranging from 469 to 779 ppm and from 6.63 ppm to 13.33 ppm, respectively, but generally within the respective limits of exposure. The examination of the indoor/outdoor (I/O) ratio of air pollutants, demonstrated that the outdoor meteorology affects only PM1 and PM2.5, as PM10 and TVOCs are strongly affected by internal sources and the activities of pupils.

 Artículos similares

       
 
Hai-Ying Liu, Daniel Dunea, Stefania Iordache and Alin Pohoata    
Exposure to airborne fine particulate matter (PM2.5) carries substantial health risks, particularly for younger children (0–10 years). Epidemiological evidence indicates that children are more susceptible to PM health effects than adults. We conduc... ver más
Revista: Atmosphere

 
Ling-Hsi Chen, Jiunyuan Chen and Chiachung Chen    
Evapotranspiration (ET) is a typical biological environmental process to influence leaf temperature, crop water requirement, and greenhouse microclimate. Affecting factors of ET include air temperature, air relative humidity, wind speed, solar radiation,... ver más
Revista: Atmosphere

 
Kati Järvi, Camilla Vornanen-Winqvist, Raimo Mikkola, Jarek Kurnitski and Heidi Salonen    
s-
Revista: Atmosphere

 
Zhi-Jie Tang, Xin Hu, Jun-Qin Qiao and Hong-Zhen Lian    
20 sets of indoor and outdoor size-segregated aerosol (SSA) samples (180 foils) were collected synchronously by using two 8 Stage Non-Viable Cascade Impactor from an office room in the central region of the megacity-Nanjing, China in winter and spring in... ver más
Revista: Atmosphere

 
James Milner, Ben Armstrong, Mike Davies, Ian Ridley, Zaid Chalabi, Clive Shrubsole, Sotiris Vardoulakis and Paul Wilkinson    
A large proportion of particulate air pollution exposure in urban areas occurs due to the penetration of outdoor pollution into the residential indoor environment. Theoretical considerations suggest that quantifying health effects due to changes to indoo... ver más
Revista: Climate