20   Artículos

 
en línea
Ping-Chang Tsai, Yu-Min Hsueh, Chang-Kuo Chen and Cheng-Chien Kuo    
Partial discharge (PD) characteristics are very important for the diagnosis of damaged transformation equipment. If the power transmission and transformation equipment fails, it will cause large economic losses, and thus prevention is better than treatme... ver más
Revista: Applied Sciences    Formato: Electrónico

 
en línea
Yao Lu, Zhibin Qiu, Caibo Liao, Zhibiao Zhou, Tonghongfei Li and Zijian Wu    
The correct identification of partial discharge types is of great significance to the stable operation of GIS. In order to improve the recognition accuracy and result of partial discharge, and to meet the requirements of real-time monitoring of GIS equip... ver más
Revista: Applied Sciences    Formato: Electrónico

 
en línea
Yanan Li and Zhaohui Li    
Partial Discharge (PD) measurements of large generators are extremely affected and hampered by noise, making the denoising of PD signal an inevitable issue. Wavelet shrinkage is the most commonly employed method for PD signal denoising. The appropriate m... ver más
Revista: Applied Sciences    Formato: Electrónico

 
en línea
Kamalaselvan Arunachalam, Balasubramanian Madanmohan, Rajesh Rajamani, Natarajan Prabaharan, Hassan Haes Alhelou and Pierluigi Siano    
The Frequency Response Analysis approach (FRA) is useful in the fault diagnosis of transformers. However, its usefulness in diagnosing any potential sources of Partial Discharge (PD) in transformers has not been thoroughly investigated so far. In this wo... ver más
Revista: Applied Sciences    Formato: Electrónico

 
en línea
Weijia Yao, Yongpeng Xu, Yong Qian, Gehao Sheng and Xiuchen Jiang    
Insulation defects that occur in gas-insulated switchgear (GIS), which is one of the most important types of equipment in the power grid, can lead to serious accidents. The ultrasonic detection method is commonly used to detect partial discharge (PD) sig... ver más
Revista: Applied Sciences    Formato: Electrónico

 
en línea
Shiming Gan, Yingang Gui, Xiaoyan Bao and Dong Chen    
Partial discharge has become a serious threat to the stable operation of gas-insulated switchgears. SOF2 is a characteristic decomposition component of SF6 decomposition components under partial discharge, which further deteriorate the severity of partia... ver más
Revista: Applied Sciences    Formato: Electrónico

 
en línea
Bo Gao, Rui Yu, Guangcai Hu, Cheng Liu, Xin Zhuang and Peng Zhou    
The pressboard surface is the electric weak link of the oil-paper insulation in transformers, and long-term partial discharge (PD) erosion is the dominant cause of degradation in pressboard. To explore the development processes of surface tracking under ... ver más
Revista: Energies    Formato: Electrónico

 
en línea
Abdullahi Abubakar Mas?ud, Jorge Alfredo Ardila-Rey, Ricardo Albarracín, Firdaus Muhammad-Sukki and Nurul Aini Bani    
This paper compared the capabilities of the artificial neural network (ANN) and the fuzzy logic (FL) approaches for recognizing and discriminating partial discharge (PD) fault classes. The training and testing parameters for the ANN and FL comprise stati... ver más
Revista: Energies    Formato: Electrónico

 
en línea
Wojciech Sikorski, Krzysztof Walczak and Piotr Przybylek    
Most power transformers operating in a power system possess oil-paper insulation. A serious defect of this type of insulation, which is associated with long operation time, is an increase in the moisture content. Moisture introduces a number of threats t... ver más
Revista: Energies    Formato: Electrónico

 
en línea
Jian Li, Xudong Li, Lin Du, Min Cao and Guochao Qian    
Ultra-high-frequency (UHF) partial discharge (PD) online monitoring is an effective way to inspect potential faults and insulation defects in power transformers. The construction of UHF PD online monitoring system is a challenge because of the high-frequ... ver más
Revista: Energies    Formato: Electrónico