Development of the engineering procedure for the thermotechnical calculation of a building envelope with air chambers and a heat­reflecting coating

Ulanbator Suleimenov    
Andrii Kostikov    
Raimberdy Ristavletov    
Medetbek Kambarov    
Ruslan Kudabayev    
Anna Vorontsova    

Resumen

The study has addressed the development of the engineering procedure for the thermotechnical calculation of a building envelope with thermal insulation in which air chambers with a heat-reflecting coating are formed.The engineering procedure implied determining the average RSI-value of the building envelope based on the calculation of a temperature field in it. To find the temperature field, a one-dimensional heat conduction problem in a multilayer building envelope was considered. The thermotechnical heterogeneities caused by the presence of alternating air chambers and dividers of insulation material were taken into account in the mathematical model using the effective thermal conductivity of a corresponding layer. This coefficient takes into consideration the convective and radiant components of heat transfer through air chambers. An expression was obtained for determining its value depending on the temperature at the junction of corresponding layers with adjacent building envelope layers. The iterative procedure was proposed that makes it possible to use this expression for determining the temperature fields in the building envelope under consideration. The geometric and thermophysical characteristics of building envelope elements, as well as the values of indoor and outdoor temperature and heat transfer coefficients of the corresponding surfaces, were used as initial data.The engineering procedure was verified by comparison with the results of three-dimensional CFD simulation, which takes into detailed account the free-convective motion in air chambers and the radiation heat exchange between thermally inhomogeneous walls of the air chamber. It was shown that the use of a one-dimensional mathematical model instead of a detailed three-dimensional one leads to errors not exceeding 2.5 %.As a result of our comparative analysis, the effectiveness of the proposed thermal insulation material having air chambers with a heat-reflecting coating was shown in comparison with the conventional approaches to building envelope thermal insulation. Calculations were performed for the case of the coldest five-day period in the climatic zone of Shymkent (Republic of Kazakhstan)

 Artículos similares

       
 
Beichen Lu, Yanjun Liu, Xiaoyu Zhai, Li Zhang and Yun Chen    
In recent years, clean and renewable energy sources have received much attention to balance the contradiction between resource needs and environmental sustainability. Among them, ocean thermal energy conversion (OTEC), which consists of surface warm seaw... ver más

 
Bohdan Petryshyn, Serhii Postupaiev, Soufiane Ben Bari and Armantas Ostreika    
The development of autonomous driving models through reinforcement learning has gained significant traction. However, developing obstacle avoidance systems remains a challenge. Specifically, optimising path completion times while navigating obstacles is ... ver más
Revista: Information

 
Xiaokai Li, Xiaolong Zhang, Faming Zhang, Jian Huang, Shixiong Tang and Zhiqing Liu    
The mountainous areas of Southwest China have the characteristics of valley deep-cutting, a large topographic gradient, complex geological structures, etc. With the development of infrastructure construction in the area, the construction of bridges acros... ver más
Revista: Water

 
Kichan Sim and Kangsu Lee    
A digital twin is a virtual model of a real-world structure (such as a device or equipment) which supports various problems or operations that occur throughout the life cycle of the structure through linkage with the actual structure. Digital twins have ... ver más

 
Fan Zhu, Meng Zhang, Fuxuan Ma, Zhihua Li and Xianqiang Qu    
Wind turbine towers experience complex dynamic loads during actual operation, and these loads are difficult to accurately predict in advance, which may lead to inaccurate structural fatigue and strength assessment during the structural design phase, ther... ver más