Redirigiendo al acceso original de articulo en 19 segundos...
ARTÍCULO
TITULO

Use of the optical lithography in the development of disposable carbon based electrodes - doi: 10.4025/actascitechnol.v35i1.11915

Lucilene Dornelles Mello    
Alexandre Kisner    
Arnaldo Pereira    
Lauro Tatsuo Kubota    

Resumen

In this study, carbon-based electrodes for disposable use were constructed using the technique of optical lithography. The process consisted in the irradiation of UV light on a layer of photosensitive resin (SU-8 50) deposited on a substrate of PVC. The pattern obtained electrode was filled with carbon paste. The electrodes were characterized by cyclic voltammetric using the reversible system Fe(CN)63-/Fe(CN)64- in KCl 0.1 mol L-1 and electrochemical impedance spectroscopy (EIS). The electrodes showed an E°? = ½ (Epa + Epc) » 229 (± 2) mV vs SCE (n = 4), with DEp » 235 (± 14) mV (n = 4). Other studies showed a linear behavior of the peak current (Ip) both anode and cathode with v1/2, probably due to diffuse contribution and/or electron transfer kinetics of the reaction. These parameters are in accordance to with those obtained for screen-printed electrode described in the literature. The good results obtained show the suitability of the electrodes for analytical applications such as development of sensors.  

 Artículos similares

       
 
Pauline Conigliaro, Marianna Portaccio, Maria Lepore and Ines Delfino    
Phenolic compounds (PheCs) are particularly relevant in many different frameworks due to their pro-oxidant and antioxidant activities. In fact, on the one hand, they are considered very dangerous pro-oxidant agents that can be present in the environment ... ver más
Revista: Applied Sciences

 
Alfonso Tramontana, Giovanni Roberto Tedesco, Sergio Gurgone, Giuseppe Acri and Alessandro Meduri    
Meibomitis is an ocular disease which leads to a dysfunction of the meibomian glands. This ophthalmologic disease may cause severe pain and obvious vision loss. The therapeutic protocol used in the treatment of this pathology consists in local and system... ver más
Revista: Applied Sciences

 
Francisco J. P. Rebelo, Joel R. M. Oliveira, Hugo M. R. D. Silva, Jorge Oliveira e Sá, Vânia Marecos and João Afonso    
The evolution of technological tools, namely affordable sensors for data collection, and the growing concerns about maintaining roads in adequate conditions have promoted the development of continuous pavement monitoring systems. This paper presents the ... ver más
Revista: Infrastructures

 
Zhan Tan, Jiu Ren, Shaoda Li, Wei Li, Rui Zhang and Tiegang Sun    
Remote sensing is widely used for lake-water-quality monitoring, but the inversion of the total nitrogen (TN) and total phosphorus (TP) of rivers and non-optical parameters is still a difficult problem. The use of high spatial and temporal resolution mul... ver más
Revista: Water

 
Miguel Arratia, Bruce Bagby, Peter Carney, Jiajun Huang, Ryan Milton, Sebouh J. Paul, Sean Preins, Miguel Rodriguez and Weibin Zhang    
We recently proposed a high-granularity calorimeter insert for the Electron-Ion Collider (EIC) that uses plastic scintillator tiles read out by SiPMs. Among its features are an ASIC-away-from-SiPM strategy for reducing cooling requirements and minimizing... ver más
Revista: Instruments