Redirigiendo al acceso original de articulo en 16 segundos...
Inicio  /  Applied Sciences  /  Vol: 10 Par: 23 (2020)  /  Artículo
ARTÍCULO
TITULO

Experimental and Numerical Evaluation of Toxic Pool Evaporation

Benjamin Truchot    
André Carrau    
Véronique Debuy    
Thibauld Penelon and Jean-Pierre Bertrand    

Resumen

To date, safety distances to toxic pool evaporation as measured by known models have been quoted in hundreds of meters, without a deeper study of the time variation of the evaporation rate. In order to evaluate this specific aspect, we designed an experimental study. This study included small-scale tests with a 0.1 m2 evaporating pool, and medium-scale tests with 1 and 2 m2 evaporating pools. For both small- and medium-scale tests, the experimental vertical velocity profile was built to reproduce an atmospheric profile after applying the Froude scaling procedure. The scope of this study focused on ammonia pool evaporation, with each test lasting long enough to highlight the time evolution of the evaporation rate. While many other parameters may have strongly influenced the evaporation rate, the influence of the most classical parameters was tested, including pool concentration, wind velocity, and ambient turbulence. During these tests, the metrology was designed to enable the measuring of evaporation rates with great precision, but other important components were also measured. This series of tests clearly showed a strong variation of the evaporation rate in the first 30 minutes after the release?the evaporation rate dropped to 20% of its initial value after this 30-min period. It is therefore obvious that such reactions should strongly influence the toxic consequences of the vapor atmospheric dispersion. The known influence of other parameters was also confirmed?typically, the higher the pool concentration and/or wind velocity, the higher the evaporation rate. The surrounding turbulence effect was also taken into consideration and was proven to have a lower influence on the evaporation rate. In light of these experiments, we present below a physical model named EVAP-Tox used to estimate the time variation of the evaporation rate of an ammonia solution.

 Artículos similares

       
 
Wenjie Shen, Suofang Wang, Mengyuan Wang, Jia Suo and Zhao Zhang    
Improving airflow pressure is of great significance for the cooling and sealing of aeroengines. In a co-rotating cavity with radial inflow, vortex reducers are used to decrease the pressure drop. However, the performance of traditional vortex reducers is... ver más
Revista: Aerospace

 
Panagiotis D. Kordas, George N. Lampeas and Konstantinos T. Fotopoulos    
The main purpose of this study comprises the design and the development of a novel experimental configuration for carrying out tests on a full-scale stiffened panel manufactured of fiber-reinforced thermoplastic material. Two different test-bench design ... ver más
Revista: Aerospace

 
Khaqan Baluch, Heon-Joon Park, Kyuchan Ji and Sher Q. Baluch    
Whilst numerical modelling is commonly used for simulation to check the design of water conveyance, sluicing and spillway structure design, the numerical modelling has rarely been compared with the physical model tests. The objective of this research pre... ver más
Revista: Water

 
Abdul Basit, Safeer Abbas, Muhammad Mubashir Ajmal, Ubaid Ahmad Mughal, Syed Minhaj Saleem Kazmi and Muhammad Junaid Munir    
This study undertakes a comprehensive experimental and numerical analysis of the structural integrity of buried RC sewerage pipes, focusing on the performance of two distinct jointing materials: cement mortar and non-shrinkage grout. Through joint shear ... ver más
Revista: Infrastructures

 
Estefanía Gómez-Gamboa, Jorge Guillermo Díaz-Rodríguez, Jairo Andrés Mantilla-Villalobos, Oscar Rodolfo Bohórquez-Becerra and Manuel del Jesús Martínez    
Revista: Infrastructures