Measuring the Beam Energy in Proton Therapy Facilities Using ATLAS IBL Pixel Detectors

Isabelle Schilling    
Claus Maximilian Bäcker    
Christian Bäumer    
Carina Behrends    
Marius Hötting    
Jana Hohmann    
Kevin Kröninger    
Beate Timmermann and Jens Weingarten    

Resumen

The accurate measurement of the beam range in the frame of quality assurance (QA) is a requirement for clinical use of a proton therapy machine. Conventionally used detectors mostly estimate the range by measuring the depth dose distribution of the protons. In this paper, we use pixel detectors designed for individual particle tracking in the high-radiation environment of the ATLAS experiment at LHC. The detector measures the deposited energy in the sensor for individual protons. Due to the limited dynamic energy range of the readout chip, several ways to measure the proton energy or range are examined. A staircase phantom is placed on the detector to perform an energy calibration relative to the NIST PSTAR stopping power database. In addition, track length measurements are performed using the detector aligned parallel with the beam axis to investigate the Linear Energy Transfer (LET) per pixel along the trajectory of individual protons. In this proof-of-principle study, we show that this radiation hardness detector can successfully be used to determine the initial proton energy for protons impinging on the sensor with an energy below 44 MeV after the range shifters. It becomes clear that an improvement of the energy resolution of the readout chip is required for clinical use.

 Artículos similares

       
 
Maisarah Musa, Hamad Yahia Abu Mhanna, Ahmad Fairuz Omar, Yasmin Md Radzi, Hanan Fawaz Akhdar, Nor Hafizah Ishak and Haytham Al Ewaidat    
The purpose of this study was to investigate the optical response of an expired External Beam Therapy (EBT3) film, which expired in 2018, using X-rays and electron beam doses. The film?s optical responses were evaluated for its usability in measuring dif... ver más
Revista: Applied Sciences

 
Ahmad Hija and Dror Michael Allon    
Before orthognathic surgery, a thorough diagnosis of the maxillofacial structure is performed for combined orthodontic?surgical treatment planning. One of the tools that are used for this collaboration is the cephalometric radiograph. Cephalometric analy... ver más
Revista: Applied Sciences

 
Giacomo D?Angeli, Francesca Zara, Alessio Belloni, Francesco Maria D?Angeli, Michele Dello Spedale Venti, Daniela Messineo, Alessandro Corsi and Gian Luca Sfasciotti    
The dental follicle (DF) is the tissue that surrounds the crown of the developing tooth. In X-ray, images it appears as a radiolucent area. The removal of an impacted mandibular third molar is a common procedure in oral surgery. The radiographic evidence... ver más
Revista: Applied Sciences

 
Johannes Leidner, Fabrizio Murtas and Marco Silari    
The GEMPix is a small gaseous detector with a highly pixelated readout, consisting of a drift region, three Gas Electron Multipliers (GEMs) for signal amplification, and four Timepix ASICs with 55 µm pixel pitch and a total of 262,144 pixels. A continuou... ver más
Revista: Applied Sciences

 
Claudiu Andrei Stan, Koji Motomura, Gabriel Blaj, Yoshiaki Kumagai, Yiwen Li, Daehyun You, Taishi Ono, Armin Kalita, Tadashi Togashi, Shigeki Owada, Kensuke Tono, Makina Yabashi, Tetsuo Katayama and Kiyoshi Ueda    
The high energy densities deposited in materials by focused X-ray laser pulses generate shock waves which travel away from the irradiated region, and can generate complex wave patterns or induce phase changes. We determined the time-pressure histories of... ver más
Revista: Applied Sciences