Inicio  /  Applied Sciences  /  Vol: 10 Par: 6 (2020)  /  Artículo
ARTÍCULO
TITULO

Biomechanical Assessment of Vertebroplasty Combined with Cement-Augmented Screw Fixation for Lumbar Burst Fractures: A Finite Element Analysis

Yueh-Ying Hsieh    
Yi-Jie Kuo    
Chia-Hsien Chen    
Lien-Chen Wu    
Chang-Jung Chiang and Chun-Li Lin    

Resumen

A hybrid fixation method, using a combination of vertebroplasty and cement-augmented screws, has been demonstrated as a useful technique for securing osteoporotic burst fractures. The purpose of this study was to assess changes in the range of motion (ROM) and stress in the spine after treating a lumbar burst fracture with this hybrid method. Five finite element models were developed: (a) intact lumbar spine (INT), (b) INT with vertebroplasty at L3 (AwC), (c) two-segment fixation of AwC (AwC-TSF), (d) AwC-TSF model with cement-augmented screws (AwC-TSF-S), and (e) INT with an L3 burst fracture treated with two-segment fixation (TSF). After loading, the models were evaluated in terms of the ROM of each motion segment, stiffness of fusion segments, and stresses on the endplates and screws. The results showed that the TSF model has a larger ROM at the instrumented segments than both the AwC-TSF and AwC-TSF-S models. The stiffness at L2?L4 under extension and lateral bending in AwC-TSF, AwC-TSF-S and TSF was approximately nine times greater than the INT model. In conclusion, the hybrid fixation method (AwC-TSF-S) results in a stiffer construct and lower ROM at instrumented segments, which may also reduce the risk of fracture of adjacent vertebrae.

 Artículos similares

       
 
Alessandro Borrelli, Giuseppe D?Errico, Corrado Borrelli and Roberto Citarella    
The objective of this study was to apply an innovative technique to manufacture a plastic automotive component to reduce its weight and costs, and guarantee its design was safe. A frontal impact sled test was simulated, and the damages to the occupant?s ... ver más
Revista: Applied Sciences

 
Bartosz Wieczorek, Mateusz Kukla, Dominik Rybarczyk and Lukasz Wargula    
Purpose: The main purpose of the research conducted was the analysis of kinematic and biomechanical parameters measured during manual wheelchair ramp-climbing with the use of the anti-rollback system and the comparison of the values tested with the manua... ver más
Revista: Applied Sciences

 
Johannes Pordzik, Anke Bernstein, Julius Watrinet, Hermann O. Mayr, Sergio H. Latorre, Hagen Schmal and Michael Seidenstuecker    
Just like menisci, articular cartilage is exposed to constant and varying stresses. Injuries to the meniscus are associated with the development of gonarthritis. Both the articular cartilage and the menisci are subject to structural changes under gonarth... ver más
Revista: Applied Sciences

 
Krystyna Hejdysz, Jagoda Goslinska, Agnieszka Warenczak, Joanna Dudzinska, Ewa Adamczyk, Pawel Sip, Jaroslaw Goslinski, Piotr Owczarek, Adam Wozniak and Przemyslaw Lisinski    
Reduced range of motion is one of the main symptoms of knee osteoarthritis. These deficits are believed to have a negative impact on activities of daily living. The aim of the study was to examine how manual therapy and closed-chain kinematic exercises a... ver más
Revista: Applied Sciences

 
Miguel Morales Ríos, Emilsy Medina Chacón, Angel Carnevali Fernández, Eber Orozco Guillén    
La investigación se enfoca en la aplicación de la Termografía Infrarroja, como método no invasivo, para evaluar posibles riesgos a sufrir de lesiones músculo esqueléticas en operarios de la industria manufacturera de neumáticos en Venezuela. En tal senti... ver más