Redirigiendo al acceso original de articulo en 15 segundos...
ARTÍCULO
TITULO

Improving energy characteristics of ac electric rolling stock by using the three-level active four-quadrant rectifiers

Oleksandr Plakhtii    
Volodymyr Nerubatskyi    
Dmytro Sushko    
Igor Ryshchenko    
Vladyslav Tsybulnyk    
Denys Hordiienko    

Resumen

In order to minimize the reactive power and higher harmonics of currents, as well as to improve the electromagnetic compatibility of electrical traction networks and systems of railroad automation, modern electric rolling stock of alternating current employ active four-quadrant rectifiers. The classical topology of a given converter is the two-level full-bridge active rectifier that ensures a power factor close to unity and the recuperation of energy to a power network. However, the high switching frequency predetermines high dynamic losses in power transistors and a low value for efficiency.It appears promising to use the three-level active four-quadrant rectifiers with a power factor correction. It has been proposed in the current work to apply a system of control over a three-level active rectifier with the two-channel equal-shifted sinusoidal PWM. The advantage of the proposed algorithm, as compared with known, is the improvement of quality of the input current and a decrease in the frequency of switching power switches, which leads to a decrease in power losses and an increase in the rectifier efficiency. The paper reports results of comparative analysis of dependences of power losses and efficiency on the switching frequency of power switches for the two-level and three-level active rectifier with the proposed control system, which confirmed the feasibility of the proposed control system. The software package MATLAB 2017b was used for simulation modeling of the two-level and three-level active rectifier, based on which we analyzed the quality parameters of electric energy, established the dependence of a harmonic distortion coefficient of the input current of an active rectifier on the switching frequency of power switches. Our study has proven the technical and economic expediency of using a circuit of the three-level active rectifier with a control system based on the two-level equal-shifted sinusoidal PWM.

 Artículos similares

       
 
Zeqin Tian, Dengfeng Chen and Liang Zhao    
Accurate building energy consumption prediction is a crucial condition for the sustainable development of building energy management systems. However, the highly nonlinear nature of data and complex influencing factors in the energy consumption of large ... ver más
Revista: Applied Sciences

 
Peng Zhang, Rixin Cheng and Yonghong Li    
Bionic herringbone riblets are applied to relieve the flow near the blade endwall in a linear compressor cascade under the incidence angle of -4° to 6° at a Reynolds number of 382,000. The herringbone riblets are placed at the endwall upstream of the bla... ver más
Revista: Aerospace

 
Junyao Zhang, Hao Zhan and Baigang Mi    
The submerged inlet exhibits good stealth characteristics and lower drag, but it has a low total pressure recovery coefficient and high distortion rate, which limits its widespread application. This paper proposes a vortex diverter aimed at enhancing the... ver más
Revista: Aerospace

 
Chan-Sol Park, Soo-Jin Ahn, Yeong-Bae Lee and Chang-Ki Kang    
In ultrasound diagnostics, acoustic absorbers block unwanted acoustic energy or prevent the reception of echo signals from structures outside the target area. Non-metallic absorbers provide a low-echoic signal that is suitable for observing the anatomy o... ver más
Revista: Applied Sciences

 
Marian Wnuk    
An important element of modern telecommunications is wireless radio networks, which enable mobile subscribers to access wireless networks. The cell area is divided into independent sectors served by directional antennas. As the number of mobile network s... ver más
Revista: Algorithms